18,19 The PK/PD studies complete dose titration studies aimed to select rational dosage regimens. Drug levels are measured on undiluted samples, diluted samples, in tissue and on individual cells. For the measurement of intracellular levels good quality standardized cell samples are required. Finally, cervical and rectal biopsies are used to determine anti-HIV activity of microbicides in explant models.20 As Selleck LEE011 yet, samples from clinical trials have not been used for this. Quantification of soluble mucosal immune factors and HIV specific
responses is possible in undiluted samples and samples diluted in a standard volume. In contrast, the dilution effect of a CVL interferes with the exact quantification and values are usually expressed as percentages. For example, a CVL performed with 10 mL saline results in a diluted sample volume ranging from 9.7 to 10.1 mL. Therefore it is important to be able to quantify the volume of cervicovaginal secretions collected and accurately approximate the dilution MK-2206 solubility dmso factor of a soluble component introduced by the washing. Lithium chloride, an inert substance, can be used to measure
the dilution factor when added to CVL21; however, the analysis can be cumbersome and requires the use of flame atomic absorption spectrophotometer.11 Alternatively, one could measure total protein or IgA.11 Furthermore, the collection of the same type of samples at multiple time points in clinical trials allows for comparisons of soluble markers within the same individual. The mean volumes collected with undiluted sampling methods are often small; Weck-Cell 50 μL, swab 200 μL, vaginal cup 500 μL, aspirator 500 μL. This disadvantage has to be taken into account when designing the objectives of a trial and the trials laboratory assays to measure the endpoints. From the start of protocol discussions, a team of clinicians, epidemiologists
and laboratory scientists should agree on sampling methodology linked to Oxymatrine laboratory assays and study the volumes needed for each assay. If the recovered volumes are thought to be insufficient, alternatives will need to be explored. For example, one could take multiple samples and pool them, dilute the sample or suspend the sample device in a standard volume, or perform a CVL. The multiplex cytokine assays were not originally validated for genital tract secretions; nevertheless, performance and experience with the multiplex is mounting and standardization efforts are ongoing.22 The multiplex kits can be custom made to fit the panel of cytokines selected for any study design.