As all subjects were resistance trained

As all subjects were resistance trained BIX 1294 concentration men, all had a full understanding of the described feeling. A circumference measure of the upper torso was also taken twice using a tension regulated tape measure (across the nipple line with the

shirt removed), and the mean of two measures was recorded. Subjects stood relaxed during these measures with their arms at their sides. These exact measures for muscle pump and circumference were taken a second time, within five minutes of completing the exercise protocol. Subjects then consumed their assigned condition and prepared for the performance tests. During this time, subjects were fitted with a heart rate monitor to be worn during the entire exercise test protocol. Following the required time (60 minutes for GlycoCarn® and 30 minutes for all other conditions), the performance tests were performed in the order described below. No other food or calorie-containing Selleck AC220 drinks were allowed during testing, but water was allowed ad libitum for the first session

and matched for all conditions and days of testing. Although water intake was matched for each subject for each condition, we did not measure hydration status of subjects. This may be considered a limitation of the present work, as hydration status has been reported to influence the hormonal environment associated with acute resistance exercise [17], which could have possibly influenced our outcome measures. Performance Testing As a measure of muscular power, bench press throws were performed using the ProSpot® device. Following a warm-up of 10% of their predetermined 1RM, subjects performed three throws using 30% of 1RM. Ninety seconds of rest was provided between each throw. The best attempt of the three throws was recorded and used in the data analysis. A detailed description

Oxaprozin of this assessment is provided elsewhere [18]; however basic procedures were as follows. Kinetic and kinematic data were acquired through the combination of a modified floor scale (Roughdeck, Rice Lake Weighing Systems, Rice Lake, WI) and a linear velocity/position transducer (VP510, Unimeasure, Corvallis, OR). The linear transducer was mounted superior to the H 89 barbell and was centrally tethered to the barbell. Measurements of force and velocity were measured directly by the modified floor scale and linear transducer, respectively. Power was calculated indirectly via inverse dynamic equations within our acquisition software (DataPac 5). Following the bench press throws, a sensor was placed on subjects’ dominant arm anterior deltoid muscle for a measure of muscle tissue oxygen saturation using Near Infrared Spectroscopy (NIRS), as described below. Subjects then performed the bench press test which involved 10 sets in the Hammer Strength™ supine bench press exercise using a load equal to 50% of 1RM.

Leave a Reply

Your email address will not be published. Required fields are marked *

*

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>